<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"><channel><title>Office Partitions blog</title><link>https://office-partitions.org.uk/blog/</link><description>Office partitioning across the UK: glazed and solid partitions, meeting rooms, private offices, acoustic and fire-rated walls, supplied and fitted.</description><language>en-gb</language><item><title>Glass partition manifestation and safety glazing rules (UK)</title><link>https://office-partitions.org.uk/blog/glass-partition-manifestation-rules/</link><guid>https://office-partitions.org.uk/blog/glass-partition-manifestation-rules/</guid><description>In UK offices, glazed partitions and doors that people could walk into must be marked with manifestation, normally in two bands at 850 to 1000 mm and 1400 to 1600 mm above floor level under Approved Document K. Glass in critical locations, such as doors, panels within 300 mm of a door and low-level glazing below 800 mm, must break safely or be protected.</description><category>Regulations</category><pubDate>Fri, 06 Nov 2026 09:00:00 +0000</pubDate></item><item><title>Accessible office partitions: door widths, vision panels and Part M</title><link>https://office-partitions.org.uk/blog/accessible-office-partitions-part-m/</link><guid>https://office-partitions.org.uk/blog/accessible-office-partitions-part-m/</guid><description>New office partitions and doors in England should follow Approved Document M, which sets minimum effective clear door widths of 800 to 825 mm for most internal doors in new buildings, a 300 mm clear space beside the leading edge, visibility zones on doors across circulation routes and limits on opening force. Alterations must not make an existing building less accessible.</description><category>Regulations</category><pubDate>Fri, 06 Nov 2026 09:00:00 +0000</pubDate></item><item><title>New office rooms: lighting, air con and fire alarm mistakes to avoid</title><link>https://office-partitions.org.uk/blog/office-partitions-lighting-hvac-fire-alarm-mistakes/</link><guid>https://office-partitions.org.uk/blog/office-partitions-lighting-hvac-fire-alarm-mistakes/</guid><description>The most common mistakes when adding office partitions are forgetting that each new room needs fire alarm detection, emergency lighting, ventilation and its own light switching, and building walls under air conditioning units or sprinkler heads. Plan electrical, mechanical and fire alarm changes alongside the partition design, not after the walls are up.</description><category>Advice</category><pubDate>Fri, 06 Nov 2026 09:00:00 +0000</pubDate></item><item><title>Office pods vs built meeting rooms: cost, acoustics and flexibility</title><link>https://office-partitions.org.uk/blog/office-pods-vs-meeting-rooms/</link><guid>https://office-partitions.org.uk/blog/office-pods-vs-meeting-rooms/</guid><description>Freestanding office pods suit one to four people for calls and short meetings, can be moved when you relocate and usually avoid building work. Partitioned meeting rooms are better value for larger groups, give more space and comfort and can be built to higher acoustic and fire standards. Many offices combine a few pods for calls with built rooms for meetings.</description><category>Comparisons</category><pubDate>Fri, 06 Nov 2026 09:00:00 +0000</pubDate></item><item><title>Office partitions in listed and period buildings: what to know</title><link>https://office-partitions.org.uk/blog/office-partitions-in-listed-and-period-buildings/</link><guid>https://office-partitions.org.uk/blog/office-partitions-in-listed-and-period-buildings/</guid><description>Partitioning a listed office building usually needs listed building consent if the work affects its special character, and carrying out such work without consent is a criminal offence. In any pre-2000 building, an asbestos refurbishment survey is needed before fixing into walls, floors or ceilings. Reversible, minimally fixed partitions that avoid cornices and features usually have the best chance of approval.</description><category>Advice</category><pubDate>Fri, 06 Nov 2026 09:00:00 +0000</pubDate></item><item><title>Framed vs frameless, single vs double glazed partitions compared</title><link>https://office-partitions.org.uk/blog/framed-vs-frameless-glass-partitions/</link><guid>https://office-partitions.org.uk/blog/framed-vs-frameless-glass-partitions/</guid><description>Frameless single-glazed partitions give the cleanest look and suit most general meeting rooms, while framed double-glazed systems give better acoustic performance, more door and blind options and a more robust finish for confidential rooms. Single glazing is usually cheaper, and double glazing costs more but can reach much higher sound reduction ratings.</description><category>Comparisons</category><pubDate>Fri, 06 Nov 2026 09:00:00 +0000</pubDate></item><item><title>How to reduce office partition costs: 12 money-saving tips</title><link>https://office-partitions.org.uk/blog/how-to-reduce-office-partition-costs/</link><guid>https://office-partitions.org.uk/blog/how-to-reduce-office-partition-costs/</guid><description>The biggest savings on office partitions come from layout and specification: using existing walls, fewer and simpler doors, standard glass sizes and single glazing where acoustics are not critical. Planning early to avoid rushed lead times, coordinating trades and getting clear like-for-like quotes also cut costs without compromising safety.</description><category>Costs</category><pubDate>Fri, 06 Nov 2026 09:00:00 +0000</pubDate></item><item><title>Building offices inside a warehouse or industrial unit: a guide</title><link>https://office-partitions.org.uk/blog/warehouse-and-industrial-unit-offices/</link><guid>https://office-partitions.org.uk/blog/warehouse-and-industrial-unit-offices/</guid><description>Offices inside a warehouse or industrial unit are usually built from insulated partitions or modular systems, at ground level or on a mezzanine. They normally need Building Regulations approval, especially for mezzanines, and must be designed for fire separation, escape, heating to at least 16 degrees in normal working conditions, lighting and protection from vehicle traffic.</description><category>Business</category><pubDate>Fri, 06 Nov 2026 09:00:00 +0000</pubDate></item><item><title>Removing office partitions: step-by-step process and making good</title><link>https://office-partitions.org.uk/blog/removing-office-partitions-step-by-step/</link><guid>https://office-partitions.org.uk/blog/removing-office-partitions-step-by-step/</guid><description>Removing office partitions safely means checking the asbestos register, isolating electrics and services, stripping out doors, glass and boards, then repairing ceilings, floors and walls. Plasterboard must be kept separate from general waste, and fire alarms, sprinklers and lighting usually need adjusting afterwards. Demountable systems can often be reused or resold.</description><category>How-to</category><pubDate>Fri, 06 Nov 2026 09:00:00 +0000</pubDate></item><item><title>Privacy for glass office partitions: film, blinds and smart glass</title><link>https://office-partitions.org.uk/blog/glass-partition-privacy-options/</link><guid>https://office-partitions.org.uk/blog/glass-partition-privacy-options/</guid><description>The cheapest way to add privacy to glass office partitions is applied frosted or patterned film, which can also meet manifestation requirements. Etched glass is permanent and more durable, integral blinds give privacy on demand in double-glazed systems, and switchable smart glass changes from clear to opaque at the touch of a button but costs far more.</description><category>How-to</category><pubDate>Fri, 06 Nov 2026 09:00:00 +0000</pubDate></item></channel></rss>
